alpha evoke 28 user manual

alpha evoke 28 user manual

Category : United Kingdom

Alpha Evoke 28 User Manual: Comprehensive Guide

This guide provides detailed instructions for the Alpha Evoke 28 boiler, a high-efficiency condensing boiler offering both central heating and domestic hot water solutions.

The Alpha Evoke 28 is a modern, high-efficiency condensing boiler designed for both comfort and economy in your home heating and hot water systems. This combination boiler is specifically engineered to deliver reliable performance while minimizing energy consumption.

As a room-sealed, fan-assisted unit, the Evoke 28 ensures safe operation by completely sealing the combustion process from the room air. It features electronic ignition and modulating fan/gas valve control for precise heat output.

This boiler provides central heating and on-demand domestic hot water at mains pressure, making it a versatile choice for various household needs. This manual will guide you through installation, operation, maintenance, and troubleshooting to ensure optimal performance and longevity of your Alpha Evoke 28.

Key Features and Specifications

The Alpha Evoke 28 boasts several key features, including its high efficiency condensing technology, reducing gas consumption and lowering heating bills. It’s a combination boiler, providing both central heating and instant hot water. The unit utilizes a modulating fan and gas valve, ensuring precise temperature control and optimal comfort.

Key specifications include a central heating output of 28kW and a domestic hot water flow rate suitable for typical household demands. It’s designed for room-sealed operation with fan assistance, enhancing safety and efficiency.

The Evoke 28 is electronically ignited, eliminating the need for a pilot light. Its compact design allows for flexible installation options, and it’s compatible with a wide range of heating systems.

Installation Procedures

Proper installation is crucial for safe and efficient operation. This section details pre-installation checks, wall mounting, pipe connections, and essential gas and electrical procedures.

Pre-Installation Checks

Before commencing installation, several critical checks are essential to ensure a safe and compliant setup. Verify the boiler is suitable for the gas supply, checking gas pressure and flow rates. Confirm adequate ventilation is available in the installation location, adhering to current regulations.

Inspect the structural integrity of the wall for secure mounting, ensuring it can support the boiler’s weight when filled with water. Confirm the flue route complies with regulations, avoiding obstructions and maintaining correct dimensions.

Ensure the electrical supply meets the boiler’s requirements, including correct voltage and earthing. Finally, verify all necessary pipework and fittings are readily available and compatible with the Alpha Evoke 28.

Wall Mounting and Pipe Connections

Securely mount the Alpha Evoke 28 boiler to a suitable wall using appropriate fixings, ensuring it is level and stable. Carefully connect the gas supply pipework, utilizing gas-tight joints and adhering to all relevant safety standards.

Connect the central heating flow and return pipes, ensuring correct pipe sizing and minimizing bends. Establish connections for the domestic hot water supply, using compatible materials and fittings.

Properly install the condensate drain, directing it to a suitable drainage point. Double-check all pipework for leaks before proceeding, and ensure adequate support is provided to prevent strain on the boiler.

Gas and Electrical Connections

Qualified personnel must perform all gas and electrical connections, adhering to local regulations and safety guidelines. Connect the gas supply to the boiler’s gas inlet, ensuring a secure and leak-proof connection using appropriate gas-tight fittings. Verify the gas supply pressure matches the boiler’s requirements.

Connect the electrical supply to the designated terminals, ensuring correct voltage and polarity. The Evoke 28 requires a dedicated electrical circuit with appropriate fuse protection.

Earth the boiler correctly for safety. Before energizing, double-check all connections and wiring. A qualified electrician should verify the electrical installation before operation.

Operating Instructions

The Alpha Evoke 28 is user-friendly, offering simple controls for central heating and domestic hot water. Follow these instructions for optimal performance and safety.

Initial Start-Up and System Filling

Before initial start-up, ensure the boiler is correctly installed and all gas and electrical connections are verified by a qualified engineer. Begin by opening the filling loop valve to introduce water into the system. Monitor the pressure gauge; the ideal operating pressure is typically between 1 and 1.5 bar.

As the system fills, bleed any air from the radiators using radiator bleed keys, starting with those closest to the boiler. Close the filling loop valve once the correct pressure is achieved. Power on the boiler and follow the on-screen prompts. The boiler will perform a self-diagnostic check. If any error codes appear, consult the troubleshooting section of this manual. Allow the system to fully heat up before adjusting temperature settings.

Setting the Central Heating Temperature

The Alpha Evoke 28 allows precise control over your central heating temperature. Access the temperature settings via the boiler’s control panel – typically using the up and down arrow buttons. The current setpoint will be displayed on the screen. You can adjust the temperature in increments of 0.5°C or 1°C, depending on the model’s settings.

Consider setting a schedule to optimize energy efficiency. Lower temperatures during periods of inactivity, such as overnight or when the house is empty. Many models offer pre-programmed modes or allow for custom schedules. Remember that lower temperatures save energy, but ensure comfort levels are maintained. Regularly review and adjust settings as needed.

Adjusting Domestic Hot Water Temperature

The Alpha Evoke 28 enables you to customize your domestic hot water temperature. Use the control panel to navigate to the hot water settings – often indicated by a tap or shower icon. Adjust the temperature using the arrow buttons, typically within a range of 40°C to 60°C. A comfortable and safe temperature is generally between 50°C and 55°C.

Be cautious of setting excessively high temperatures, as this can increase the risk of scalding. Lower temperatures conserve energy, but ensure sufficient heat for your needs. Some models feature ‘comfort’ modes for faster heating or ‘eco’ modes for energy savings. Regularly check and adjust the temperature to maintain optimal performance.

Troubleshooting Common Issues

This section details solutions for typical problems, including ignition failures, low pressure, and error codes, helping you resolve issues with your Alpha Evoke 28.

Boiler Not Igniting

If your Alpha Evoke 28 boiler fails to ignite, several factors could be responsible; First, verify the gas supply is active and the boiler is receiving gas. Check that the electrical connection is secure and the boiler has power.

Ensure the system is properly vented and there are no airlocks in the system. A low gas pressure or a faulty ignition component can also prevent ignition. If the issue persists, reset the boiler by turning it off and on again.

Consult the error code display for specific diagnostics. If these steps don’t resolve the problem, contact a qualified gas engineer for assistance, as attempting repairs yourself could be dangerous and void the warranty.

Low Pressure Problems

Experiencing low pressure on your Alpha Evoke 28 boiler often indicates a water leak within the central heating system. Carefully inspect all visible pipes, radiators, and the boiler itself for any signs of dampness or dripping water.

A gradual pressure loss usually points to a slow leak, while a sudden drop suggests a more significant issue. To temporarily resolve low pressure, you can repressurize the system using the filling loop, following the instructions in the ‘Initial Start-Up’ section.

However, repressurizing is a temporary fix; identifying and repairing the leak is crucial. If you cannot locate the leak or the pressure continues to drop, contact a qualified heating engineer for professional assistance.

Error Codes and Their Meanings

The Alpha Evoke 28 boiler utilizes error codes to diagnose potential issues. These codes are displayed on the boiler’s control panel, providing valuable information for troubleshooting. A flashing code indicates a fault requiring attention.

Common codes include: codes relating to flame detection issues, gas supply problems, or pump failures. Refer to the complete error code list in the full installation and servicing instructions (available as a PDF download).

Attempting to reset the boiler after noting the code may resolve minor faults, but persistent codes necessitate professional assistance. Do not attempt repairs yourself; always contact a qualified heating engineer for diagnosis and repair.

Maintenance and Servicing

Regular maintenance ensures optimal performance and longevity of your Alpha Evoke 28 boiler. Annual servicing by a qualified engineer is crucial for safety.

Regular Maintenance Tasks

To maintain your Alpha Evoke 28 boiler’s efficiency and reliability, several routine checks can be performed by the user. Regularly visually inspect the boiler for any leaks or signs of corrosion. Ensure the boiler casing is kept clean and free from obstructions to allow for proper ventilation.

Check the system pressure monthly, ensuring it remains within the manufacturer’s recommended range – typically between 1 and 1.5 bar. If pressure is low, follow the instructions in the ‘Initial Start-Up’ section to repressurise.

Periodically check the flue terminal is unobstructed by debris or snow. Do not attempt any internal repairs or servicing yourself; always consult a qualified Gas Safe registered engineer for these tasks.

Annual Servicing Requirements

An annual service by a qualified Gas Safe registered engineer is crucial for the safe and efficient operation of your Alpha Evoke 28 boiler. This service includes a comprehensive inspection of all gas connections, burner components, and safety devices. The engineer will analyze combustion efficiency, ensuring optimal performance and minimal emissions.

They will also check the flue for blockages and test the boiler’s safety features, such as the carbon monoxide detector. Regular servicing helps identify potential issues before they escalate, preventing costly repairs and ensuring your boiler operates safely. Keep a record of all servicing carried out, including dates and engineer details.

Safety Information

Always be aware of carbon monoxide risks. The Alpha Evoke 28 features safety mechanisms, but annual servicing by a qualified engineer is essential.

Carbon Monoxide Warnings

Carbon monoxide (CO) is a colorless, odorless, and highly toxic gas. Exposure can be fatal. The Alpha Evoke 28 boiler is designed with safety features to minimize CO production, but proper installation, ventilation, and regular maintenance are crucial. Never ignore potential signs of CO leakage, including headaches, dizziness, nausea, fatigue, or flu-like symptoms.

Install a certified carbon monoxide detector in a central location near the boiler, following the manufacturer’s instructions. Test the detector regularly to ensure it’s functioning correctly. If the alarm sounds, immediately evacuate the premises and contact emergency services or a qualified Gas Safe registered engineer. Do not attempt to diagnose or repair the issue yourself.

Ensure flue and chimney are clear of obstructions and properly maintained to allow for safe exhaust of combustion gases. Regular servicing helps identify and address potential CO risks.

Boiler Safety Features

The Alpha Evoke 28 boiler incorporates several safety features designed to protect users and property. These include a flame supervision device which shuts off the gas supply if the flame is extinguished, preventing gas accumulation. A high-limit temperature sensor prevents overheating by halting operation if excessive temperatures are detected.

The boiler also features automatic air venting to maintain optimal system pressure and efficiency. A frost protection system activates during cold temperatures to prevent freezing and potential damage. Furthermore, the Evoke 28 includes a pressure relief valve to regulate system pressure and prevent over-pressurization.

Regular servicing ensures these safety features function correctly. Never attempt to bypass or disable any safety device.

Technical Specifications

The Alpha Evoke 28 boasts detailed specifications including dimensions, weight, and gas consumption rates, crucial for installation and optimal performance understanding.

Dimensions and Weight

Understanding the physical characteristics of the Alpha Evoke 28 is vital for ensuring correct installation and adequate space allocation within the property. This boiler is designed for wall mounting, optimizing space utilization. Precise dimensions are crucial for plumbers and installers to plan pipework and ventilation effectively.

Typically, the Alpha Evoke 28 measures approximately 700mm in height, 400mm in width, and 290mm in depth. These measurements are approximate and should be verified with the official installation guide for the most accurate figures. The unit’s weight is around 29 kilograms, meaning appropriate wall fixings and support are essential for safe and secure installation.

Consider these dimensions during the planning phase to avoid any potential issues during the installation process, ensuring a seamless and efficient setup.

Gas Consumption Rates

Understanding the gas consumption of your Alpha Evoke 28 is crucial for estimating running costs and ensuring efficient operation. The boiler’s consumption varies depending on the heating demand and hot water usage. The Evoke 28 has a maximum input rate of 28kW, translating to approximately 2.98 kg/h of natural gas consumption at maximum output.

For central heating, the consumption will fluctuate based on the set temperature and external weather conditions. Domestic hot water usage also significantly impacts gas consumption. Monitoring your gas bills and understanding these rates will help you optimize energy usage and potentially reduce costs.

Refer to the full technical specifications in the user manual for detailed consumption figures under various operating conditions.

Downloading the User Manual (PDF)

Accessing the Alpha Evoke 28 user manual in PDF format is simple and provides a convenient, offline resource for all your boiler-related needs. You can easily download the manual from the official Alpha Boilers website, or through various online plumbing and heating resource platforms.

The PDF manual contains comprehensive information, including installation instructions, operating guidelines, troubleshooting tips, and detailed technical specifications. Downloading the manual ensures you always have access to vital information, even without an internet connection.

Ensure you download the correct manual version for the Evoke 28 to guarantee accuracy and relevance.


Log out of this account

Leave a Reply